Degree: Doctor

Projects
This CIQUP member does not yet have any projects linked with him.
Publications
Showing 5 latest publications. Total publications: 51
Show all publications
1. Towards point-of-care tests for protein detection at the attomolar level via disposable pollen-based nanoplasmonic probes grafted with polymer-based receptors, Pitruzzella, R; Silva, AT; Ribeiro, JA Mendes, J Coelho, LCC; Pasquardini, L; Seggio, M; Marzano, C; Arcadio, F; Cicatiello, D; Zeni, L; Jorge, P; Cennamo, N in BIOMEDICAL OPTICS EXPRESS, 2026, ISSN: 2156-7085,  Volume: 17, 
Article,  Indexed in: crossref, scopus, unpaywall, wos  DOI: 10.1364/boe.581429 P-01A-VC3
Abstract A point-of-care test (POCT) based on low-cost and highly sensitive disposable chips was designed for the sensitive and selective detection of proteins. In particular, a pollen-based plasmonic nanostructured probe coupled, for the first time, with biomimetic receptors custom-designed as molecularly imprinted nanoparticles (MIP-NPs) for protein recognition, was developed and interrogated by an extrinsic optical fiber (OF)-based scheme. To this purpose, bovine serum albumin (BSA) was chosen in a proof-of-concept frame as an example of a protein. (c) 2026 Optica Publishing Group under the terms of the Optica Open Access Publishing Agreement

2. Fast Hydrogen Detection via Optical Fibers Coated with Metal Hydride Thin Films, Santos, AD; Almeida, MAS; Mendes, JP de Almeida, JMMM; Coelho, LCC in SENSORS, 2026, ISSN: 1424-8220,  Volume: 26, 
Article,  Indexed in: crossref, scopus, wos  DOI: 10.3390/s26113285 P-01B-N4R
Abstract Detection of leaks in hydrogen (H2) infrastructure is required on a large scale to enable a safe widespread use of this clean energy source. Sensing solutions must be low-cost, use scalable fabrication methods and allow multiplexed detection while providing reliable safety alarms as fast as possible. Optical methods can make this possible while avoiding the risk of ignition due to electronics at the point of detection. Metal hydride-based micro-mirror configurations benefit from a simple interrogation scheme, as long as the sensitive element can produce a large optical response. Magnesium thin films undergo a drastic variation of properties when hydrogenated, making them suitable for this application. In this work, a micro-mirror device using single-mode fibers capable of detecting the presence of H2 with a loading t10 and t90 of 1.2 and 3.0 s, respectively, is demonstrated. A complete interrogation unit was developed, presenting a solution suited for widespread deployment using industry-standard optical components and equipment.

3. Compact fiber optic system for in-situ concrete condition assessment, Faria, RP; da Silva, PM; Santos, AD; Carvalho, JPM; de Almeida, JMMM; Coelho, LCC; Mendes, JP in OPTICS AND LASERS IN ENGINEERING, 2026, ISSN: 0143-8166,  Volume: 205, 
Article,  Indexed in: crossref, scopus, wos  DOI: 10.1016/j.optlaseng.2026.109951 P-01C-NEX
Abstract Concrete structures require precise temperature and humidity monitoring during curing to ensure optimal strength and to prevent defects such as cracking. A compact optical sensing system was developed using a single fiber that can be embedded directly within the concrete. When paired with a spectral interrogation unit operating in the low-loss single-mode communications band of 1500-1600 nm, the system functions as both a temperature and relative humidity (RH) sensor. Temperature monitoring is achieved using a Fiber Bragg Grating, while humidity sensing is provided by a Fabry-Perot interferometer (FPI) at the fiber tip. The interferometer cavity is formed with a layer of polyvinylpyrrolidone (PVP), an RH-sensitive polymer. The system exhibited a response time of approximately 3 h and operated over a relative humidity range of 50-95% RH and a temperature range of 30-60 degrees C, with normalized free spectral range sensitivities of the FPI up to 35 m(-1)/%RH at high humidity levels. The system was validated using a small-scale 50-day in-concrete test.

4. Towards Haemoglobin Detection in Finger-Prick Sampling via Low-Cost Disposable Sensor Chips Based on eMIPs on Plasmonic Optical Fiber Probes, Pitruzzella, R; Cicatiello, D; Marzano, C; Passeggio, F; Gentile, L; Ribeiro, JA Mendes, JP Coelho, LCC; Portella, G; Capellupo, MC; Casale, M; Zeni, L; Jorge, PAS; Cennamo, N in NANOMATERIALS, 2026, ISSN: 2079-4991,  Volume: 16, 
Article,  Indexed in: crossref, scopus, unpaywall, wos  DOI: 10.3390/nano16100602 P-01C-7M1
Abstract Haemoglobin (Hb) concentration is a key biomarker for several diseases. Traditional laboratory methods often have limitations due to their time-consuming nature, the need for skilled personnel, or the use of high-cost instrumentation. This work presents a sensing strategy for developing new point-of-care tests (POCTs) for Hb detection via a proof of concept. The proposed sensing approach is implemented using plasmonic plastic optical fiber (POF) sensor chips that integrate an electropolymerized molecularly imprinted polymer (eMIP) film on the plasmonic surface for Hb-selective detection. The developed sensor system demonstrates an ultra-low detection limit of 80 fM in buffer, about five orders of magnitude lower than that of other comparable Hb sensors. Selectivity tests against common interfering proteins, such as bovine serum albumin (BSA) and immunoglobulin G (IgG), confirmed high specificity towards the target analyte. Moreover, the sensor's performance was tested using a whole-blood sample, yielding results consistent with those of standard haematology analysis. The proposed sensor system, based on simple equipment, provides a quick (about 10 min) and cost-effective (about 10 euros per chip) label-free diagnostic tool for POCTs in real-world scenarios, such as finger-prick sampling, offering a less invasive alternative to traditional laboratory methods, towards devices useful for Internet of Medical Things (IoMT).

5. Electrochemical Methods for Ammonia Nitrogen Detection-a Review, Mendes, JP Coelho, LCC; Ribeiro, JA in ACS ELECTROCHEMISTRY, 2026, ISSN: 2997-0571,  Volume: 2, 
Review,  Indexed in: crossref, scopus, wos  DOI: 10.1021/acselectrochem.6c00130 P-01C-REV
Abstract Over the last decades, considerable research efforts have been devoted to the determination of total ammonia nitrogen (TAN) due to its critical importance across several fields. This review aims to highlight the potential of electrochemical methods for ammonia nitrogen sensing, with emphasis on potentiometric, amperometric, and conductometric approaches. It begins by addressing the chemical and biological relevance of ammonia in diverse contexts, ranging from vital physiological functions in the human body (urea cycle, disease biomarker), quality parameter in drinking water to its key involvement in environmental processes (the nitrogen cycle), and food safety and industrial applications (e.g., livestock, agriculture). Then, a general overview of the main methods for ammonia nitrogen quantification is provided. After that, most impacting achievements on electrochemical methods for ammonia nitrogen sensing are discussed from several perspectives, including selectivity in complex environments, sensitivity and detection levels achieved, improvements in set-up design and functionality (such as simplicity, cost-effectiveness, miniaturization for on-site, real-time, and continuous monitoring), and multiplex detection capabilities. In addition, current limitations of ammonia electroanalytical approaches, future perspectives, and emerging research trends in TAN sensing technologies are addressed in a dedicated chapter. Finally, the last section focuses on current achievements of state-of-the-art electrochemical solutions for ammonia nitrogen detection and highlights their substantial advances over conventional analytical methods.